A Buffalo LinkStation that had been treated as a backup for years, quietly shedding files. It held one disk. Whatever people assume about network storage, a single-bay NAS has no redundancy at all — it is one drive in a box on the network.
A client noticed files going missing from their Buffalo LinkStation. Not all at once — a folder that would not open one week, a document returning unreadable content the next, and a NAS that had generally become slower to browse. Attempts to copy material off produced I/O errors and, twice, crashed the machine doing the copying.
The unit had been in service for years as the household and business backup, which is the part worth pausing on. It was a single-bay LinkStation: one 3.5-inch Seagate drive inside a network enclosure. There was no second copy of anything on it, and no redundancy of any kind.
The drive was mechanically sound — no clicking, no grinding, no spin-up trouble. What it had was a substantial and growing population of bad sectors, spread across the disk rather than concentrated. Where those sectors coincided with the file system's index structures, entries had become unreadable, which is exactly why files and folders were disappearing rather than merely failing to open.
The pattern explains everything the client had seen. A file whose index entry survived opened normally. One whose entry was damaged vanished from the listing entirely. One whose contents sat partly in a bad region opened and returned nonsense. Three different symptoms, one underlying cause.
Repairing the file system in place would have been the obvious move and the wrong one. On a drive shedding sectors, a repair tool grinds through the areas already failing and resolves what it cannot read by discarding entries — precisely the records needed to rebuild the structure.
The disk was imaged instead, in graduated passes: a fast first sweep with retries disabled to bank everything that read immediately, then successive passes over the gaps with longer timeouts, reading in both directions, with the drive rested between them. That order matters on a deteriorating disk, because it secures the bulk before the drive worsens. From the completed image the ext file system was rebuilt, with surviving index structures read directly and damaged ones reconstructed from the file system's own redundant copies.
Documents were opened in their applications and photographs verified by rendering rather than counting — the whole problem had been material that appeared present and was not. Folders reported missing by the client were checked specifically against what came back.
About 99% recovered, returned on fresh media. The shortfall was confined to files whose contents and index entries both fell in bad regions.
The client replaced the LinkStation with a two-bay unit and, more importantly, added a copy that is not in the same building. A mirrored NAS would have survived this particular failure; it would not have survived a fire, a theft or a ransomware run, and by then the habit of treating one device as the backup was the real problem.
Network storage feels safer than a drive on a desk and, in a single-bay unit, it is exactly as exposed — there is no second copy and no redundancy. If files are disappearing, opening as nonsense, or producing I/O errors on copy, the disk is shedding sectors and that spreads. Stop using it rather than running a repair tool. NAS and RAID recovery from £500 +VAT; a single external or NAS disk from £300 +VAT, after a free 48-hour diagnostic.
Get the device to us for a free diagnostic and a quick note on what went wrong — an engineer looks it over and puts your exact quote in writing before anything is started.
The route to your data starts with the device reaching us. Box it up securely, tuck your contact details inside, and send it across — after the free diagnostic, we put your exact price in writing before a single step is taken.
Sending it by post? Go with a tracked, insured service. Prefer to bring it round? Our door is open Monday to Friday, 9am to 5:30pm — just pack the device as described above beforehand.
Prefer to get a sense of things first? Complete the form with a bit more about the fault and an engineer will look it over and send back a tailored quote.
We’ll get back to you soon. Anything pressing, call 01865 593000.
Usually bad sectors coinciding with the file system's index structures. A file whose entry survives opens normally; one whose entry is damaged vanishes from the listing entirely; one whose contents sit in a bad region opens and returns nonsense. Three symptoms, one cause.
Only if it holds more than one disk in a redundant arrangement. A single-bay unit like a basic LinkStation is one drive in a network enclosure — no second copy, no redundancy. It feels safer than a drive on a desk and is exactly as exposed.
No. On a drive shedding sectors, repair tools grind through the areas already failing and resolve what they cannot read by discarding entries — which are the records a recovery would use to rebuild the structure. Stop using it instead.
Because a deteriorating drive may not survive a single long sweep. A fast first pass banks everything that reads immediately — usually the large majority — and later passes revisit only the gaps, so the bulk is already secured if the drive worsens.
A single NAS disk is from £300 plus VAT; multi-bay units are array work from £500 plus VAT. Fixed in a written quote after a free 48-hour diagnostic, with most jobs no fix, no fee.